ToolsVault
Directory
Structural Concrete & Rigging

Precast Concrete Tilt-Up Wall Panel Weight & Rigging Crane Calculator

Calculate precast and tilt-up concrete wall panel weight (tons/lbs), lifting inserts, center of gravity, crane pick radius, and crane boom capacity limits.

Panel Dimensions

Normal weight reinforced concrete: 150 lb/ft³
Total Panel Weight

-- Tons

0 lbs
Concrete Volume

-- CY

Cubic Yards required
Recommended Crane Size

-- Ton Crane

75% Load Chart Safety Margin

Rigging & Suction Breakdown

Casting Bed Breakaway Suction (1.25x)

-- Tons

Initial peeling force from slab
Lifting Inserts Recommendation

4-Point or 8-Point Rig

Meadow Burke / Dayton Superior clutches

Rigging & Erection Engineering Note:

Tilt-up panel erection requires accounting for the initial breakaway suction coefficient (typically 20% to 30% additional force) when peeling the green panel off the casting slab. A crane's rated capacity diminishes drastically with boom radius; ensure the crane chart exceeds the total rig plus rigging hardware at the maximum working radius.