🌐 Commercial Geothermal District & 5G Ambient Loop Sizer

5GDHC & BTES Engineering
5th Generation District Heating & Cooling (5GDHC) Ambient Temperature Loop (ATL) Plant & Borehole Thermal Energy Storage (BTES) Sizer. Models bidirectional uninsulated thermal networks, decentralized water-source heat pumps, waste heat recovery, 100% cooling tower elimination, IRA Section 48 ITC (30%–50%), and 25-year LCOE/NPV economics.
Load Archetype Preset:
🏢 District Scale & Thermal Loads
sq ft
Cumulative floor area of all interconnected buildings on loop.
Tons
MBH
%
Non-coincident peak diversity benefit.
kW thermal
Data centers, sewers, or refrigeration rejected to loop.
FLH/yr
FLH/yr
🌱 5G Ambient Loop & Borehole Field (BTES)
°F
ft / well
EER
COP
💰 Capital Costs, IRA ITC & Tariffs
$/ft drilled
$/ton
$/ton
$/therm
$/kWh
Borehole Field Linear Feet
284,000 ft
568 vertical wells @ 500 ft
5G Ambient Loop Flow Rate
3,744 GPM
Bidirectional uninsulated loop @ 12°F ΔT
Shared Thermal Energy
32.4%
Direct heat sharing + 3,942 MWh waste heat
Annual Operating Savings
$418,200/yr
Simple Payback: 6.8 Years
🗺️ 5G Ambient Temperature Loop (ATL) Energy Exchange
55°F - 80°F Bidirectional Shared Water
📑 Engineering Spec & Environmental Yield
Design Parameter Legacy Central Plant Baseline 5G Geothermal District (5GDHC) Variance / Net Benefit
Peak Thermal Diversified Capacity 2,400 Tons / 28,000 MBH 1,872 Tons / 21,840 MBH -22.0% (Coincident Peak Sizing)
On-Site Fossil Gas Combustion 339,000 Therms/yr 0 Therms (100% Electrified) -100% Gas Eliminated
Cooling Tower Water & Chemical Consumption 6,820,000 Gal/yr 0 Gal/yr (Closed Ground Loop) 6.82M Gal/yr Conserved
Annual Carbon Emissions (Scope 1+2) 3,240 Metric Tons CO₂e 1,180 Metric Tons CO₂e -2,060 Tons/yr (-63.6%)
Total Gross Project CAPEX $6,800,000 (Central Chiller/Boiler) $10,278,000 (Wells + ATL + WSHP) +$3,478,000 Premium
IRA 48 ITC + Utility Incentives $0 -$5,047,200 Subsidized Decarbonization
Net Capital Outlay (Post-Incentive) $6,800,000 $5,230,800 -$1,569,200 First-Cost Advantage
25-Year Life Cycle Net Present Value (NPV @ 6%) Baseline Reference +$4,625,000 IRR: 24.8%
⚡ Match Certified Geothermal Contractors
💡 5th Generation District Energy (5GDHC) Engineering Insights
Why does 5GDHC use uninsulated bidirectional ambient water loops?
Unlike 3rd/4th generation steam or high-temperature hot water systems that lose 15%–30% of their heat during distribution, 5G loops circulate water at ground ambient temperatures (55°F to 80°F). Heat loss to the soil is negligible or beneficial, completely eliminating expensive pre-insulated piping while allowing raw HDPE pipe to function as an extended auxiliary ground heat exchanger.
How does simultaneous heating and cooling create 'Free' thermal energy?
In mixed-use districts, data centers, labs, and commercial offices reject heat into the ambient loop while residential and healthcare buildings simultaneously absorb heat for space and domestic water heating. The loop directly transfers thermal energy between buildings without cycling through the ground borefield, maximizing overall coefficient of performance (system COP > 6.0).
What are the IRA Section 48 ITC qualification rules for commercial geothermal?
Under the Inflation Reduction Act, geothermal ground loop heat pumps qualify for a baseline 30% Investment Tax Credit (ITC) if prevailing wage and apprenticeship requirements are satisfied. Projects meeting domestic content thresholds gain an extra +10%, and projects located in designated energy communities gain another +10%, yielding up to 50% direct tax credit or direct pay (Section 6417) for non-profits and municipalities.