Solar Lease Protocol

Commercial Solar Roof Lease & Structural Protocol

🏗️ Structural Dead Load & Roof Integrity

  • ✅ Ballasted Dead Load: Maximum 3.5 to 5.0 lbs/sqft distributed load; PE certified stamp required for structural joists.
  • ✅ Membrane Warranty: Racking pads must use manufacturer-approved sacrificial slip sheets to preserve 20-yr TPO roof warranty.
  • ✅ Wind Uplift Engineering: Aerodynamic wind deflector fairings engineered for ASCE 7-16 120+ MPH wind gusts.

⚡ Electrical Interconnection & Main Switchboard

  • ✅ Supply-Side Tap: Line-side tap between utility meter and main breaker to bypass 120% NEC 705.12 busbar rules.
  • ✅ Rapid Shutdown (NEC 690.12): Module-level power electronics (MLPE) reducing DC conduit voltage to <30V within 30s.
  • ✅ Transformer Sizing: Dedicated step-up dry-type transformer for 480V 3-phase commercial service export.

📜 25-Year PPA Lease Covenants

  • ⚠️ Roof Repair Protocol: Developer removes and reinstalls modules 1x during term at developer cost for necessary reroofing.
  • ⚠️ Environmental Credits (SRECs): Contract explicitly states whether SRECs transfer to host or remain with solar asset owner.
  • ✅ Decommissioning Escrow: 100% funded asset removal and roof membrane restoration escrow starting in Year 15.

💰 Default, Buyout & True-Up Metrics

  • 💎 Fair Market Value (FMV) Buyout: Host possesses purchase option at Years 6, 10, 15, and 20 based on independent FMV appraisal.
  • 💎 Production Guarantee: Developer guarantees 90% of P50 annual generation modeled; pays delta at utility tariff rate.